17
MS146 Manual
Bar Code Symbologies, continued
Code 93
Enabled toggles the ability for the keyboard/scanner to read
Code 93 on or off. Default is “Yes”.
•
Code ID is a user-definable identification letter for Code 93,
which is referred to in the “Use Code ID” function (see page 11).
Default is letter “L”.
•
Minimum Length defines the minimal length the user will accept
for a valid bar code. Default is “1”.
•
Maximum Length defines the maximum length the user will
accept for a valid bar code. Default is “48”.
•
MSI / Plessey Code
Enabled toggles the ability for the keyboard/scanner to read MSI
/ Plessey Code on or off. Default is “Yes”.
•
MSI Code ID is a user-definable identification letter for MSI
Code, which is referred to in the “Use Code ID” function (see
page 11). Default is letter “O”.
•
Plessey Code ID is the same as MSI Code ID (above), but
instead applicable to Plessey Code. Default is the letter “P”.
•
Send Check Digit toggles whether or not to send a check digit.
Default is “No Send”.
•
Check Digit Formula defines the formula to calculate the check
digit. Options are: “Double Module 10”, Module 11 Plus 10”, and
“Single Module 10”. Default is “Double Module 10”.
•
Minimum Length defines the minimal length the user will accept
for a valid bar code. Default is “1”.
•
Maximum Length defines the maximum length the user will
accept for a valid bar code. Default is “16”.
•