Switch # Function Switch Switch Switch NOTES:
1, 2, 3, 6 Communication
Interface
SW1 SW2 SW3 SW6
RS232 OFF OFF OFF Also set 4&5
IrDA and RS232 ON OFF OFF 9600 baud
IrDA ONLY ON ON OFF Also set 4&5
IR Direct Mode ON ON OFF ON 9600 baud
802.11b and RS232 OFF OFF ON Also set 4&5
802.11b ONLY OFF ON ON Also set 4&5
BT and RS232 OFF OFF ON Also set 4&5
BT ONLY OFF ON ON Also set 4&5
4 & 5 Comm. 1 Baud Rate SW4 SW5 Serial RS232 Rate
38,400 Off Off BT & 802
19,200 Off On
9,600 On Off
2,400 On On
4 & 5 Comm. 2 Baud Rate SW4 SW5 IrDA Rate
9,600 On Fixed
9,600 t0 38400 Baud Off Variable
6 Parity Enabled ON
Parity Disabled OFF
7 Parity Enabled ON
Parity Disabled OFF
8 Auto Power Save SW8 Manual ON/OFF
Power save disabled OFF Auto Power Down
Power save enabled ON
Table C.0 - Dip Switches and their functions
Note: The MP300 printer also supports direct IR printing. For direct IR to work you
need Dip switches 1 and 6 in the ON position and all other Dip switches need to be
OFF.
Please note that if Dip Switch # 1 is OFF then the function of Dip Switch # 6 is as
described in the table above. If Dip Switch # 1 is ON then Dip Switch # 6 being ON or
OFF determines whether we are in Direct IR or regular IrDA mode.
C.1.0 Serial Communication Rate and Parity
The RS232C Interface signals for the MP300 Series printers are terminated on a 6
PIN RJ type data connector located on the side of the printer. Six connections are
provided from the Serial Interface to the host computer. A minimum of two connections
is required for operation, RXD – pin 3 and Common – pin 1.The proper baud rate
and protocol settings are required to communicate with the host device. The printer
defaults to 19200 BAUD, 8 DATA BITS, NO PARITY BIT, and one STOP BIT on initial
power up. Two communication handshaking protocols are supported by the MP300,
Serial Busy protocol and XON/XOFF protocols.
C.1.1 Serial Busy Protocol
For the serial busy handshaking mode, request to send printer input (RTS) and clear
to send printer output (CTS) are used to control data ow to and from the printer.
The RTS and CTS are considered to be valid or active when the signal level is positive
(3 to 12VDC). A positive RTS signal from the host device enables the printer. The RTS
signal is monitored during data transmission from the printer to the host device, the
printer transmits data to the host device only if RTS input is high. The printer raises
CTS output when it is ready to accept data. The printer lowers CTS line when the
print buffer has less than 256 unused locations.
C.1.2 XON/XOFF PROTOCOL
For the XON/XOFF handshaking mode, the printer transmits XON (0x11) when it is
ready to accept data, and XOFF (0x13) for the print buffer has less than 256 unused
locations. Under XON/XOFF protocol, the data ow out of the printer’s serial port is
halted on receipt of XOFF from Host device and resumed on receipt of XON.
C.1.3 RS232C CONNECTIONS
The RS232C Interface signals for the Unitech MP300 are terminated on a 6 PIN RJ25
type data connector located at the back of the printer.
Six connections are provided from the Serial Interface to the host computer. The table
below lists the Serial Interface signals and pinouts on the RJ25 connector while pin
locations are shown in Figure 2.
A minimum of two signal connections are required for operation, RXD - pin3 and
Common - pin1.